1-Phase Metered ATS

110V / 208V / 230V

Most data centers provide power source redundancy in order to ensure critical devices have no power related downtime. Many rackmount IT devices, however, are not designed to take advantage of power redundancy. Metered MD Automatic Transfer Switches (ATS) are ideal for single-corded network devices and entry-level servers that are not designed with power redundancy. MD meter of the ATS provides a local 3-digit RMS current measurement with accuracy ± ( 3% of the reading + 5 last digits ) RMS. It helps avoid current overload in a high density equipment environment.

Metered Automatic Transfer Switch (ATS)

Most data centers provide power source redundancy in order to ensure critical devices have no power related downtime. Many rackmount IT devices, however, are not designed to take advantage of power redundancy. Metered MD Automatic Transfer Switches (ATS) are ideal for single-corded network devices and entry-level servers that are not designed with power redundancy. MD meter of the ATS provides a local 3-digit RMS current measurement with accuracy ± ( 3% of the reading + 5 last digits ) RMS. It helps avoid current overload in a high density equipment environment.

Play Video

  • 1U Metered ATS

    • Single Circuit
  • 2U Metered ATS

    • Single Circuit
  • 2U Metered ATS

    • Dual Circuit

Key Benefits

  • Metered - Input Switching Locally

    Input Switching Locally

    Sometimes manual power input switching function is essential, especially during the maintenance service in data center. InfraPower® ATS is bundled with an Input Preference Switch. It allows user to set the power source preference to supply the output.
  • Metered - Power Redundancy for Single Corded Devices

    Power Redundancy for Single Corded Devices

    Most data centers provide power source redundancy in order to ensure that critical devices have no power downtime issue. Some rackmount IT devices, however, are not designed with power redundancy. For single-corded devices, InfraPower® ATS is a perfect fit to provide power fallback. It includes dual power inlets, for connection to both a primary power source and a redundant, secondary power source.
  • Metered - Auto Switching Relay for Seamless Power Transfer

    Auto Switching Relay for Seamless Power Transfer

    InfraPower® ATS offers a simple but reliable solution for automatically sensing power loss and seamlessly switching to a secondary power source. The power source transfer time is seamless to the connected equipment, making sure that the switching occurs safely between the two input power sources. After switching to a backup power source, it can also switch power back to the primary input after power has been restored.
  • Metered - Accurate Local Current Measurement

    Accurate Local Current Measurement

    MD meter provides a local 3-digit RMS current measurement with accuracy ± ( 3% of the reading + 5 last digits ) RMS. It helps avoid current overload in a high density equipment environment. A Blue LED indicator allows easy local reading of current, especially when there is no lighting installed inside the rack as is typical in a data center environment.
  • Metered - Extensive Selection &  Quick Delivery

    Extensive Selection & Quick Delivery

    The leading edge ATS solution provides the widest range of configurations with shortest lead-times in the market : It offers 110V / 208V / 230V models with input range from 10A to 32A, outlet number from 1 to 24 and variety of outlet types ( e.g. NEMA, C13, C19, UK, Schuko, French, etc ). Custom configurations are available upon request.

Hardware

InfraPower Metered ATS Hardware Diagram
  1. Local Current Meter
  2. Input Preference Switch
  3. Circuit Breaker
  4. Power LED – primary input
  5. Power LED – secondary input
  6. Power LED – outlets
  7. Primary Input attached with 3M cord & inlet plug
  8. Secondary Input attached with 3M cord & inlet plug
  9. Outlets

Redundant Power

Automatic Transfer Switches (ATS) provide fail-safe power redundancy. A rack ATS has dual input power cords supplying power to the connected load. If the primary power source becomes unavailable, the rack ATS will seamlessly source power from the secondary source without interrupting critical loads.

Metered ATS Redundant Power

Accessories

MCB - Magnetic Circuit Breaker

Magnetic Circuit Breaker
MCB

  • Overload reset button (Fuse) or switch (MCB)
  • Safety Regulatory : UL / cUL / CSA / TUV / CCC / VDE
  • 110V / 208V : 15A, 20A & 30A
  • 230V : 10A, 13A, 16A, 20A & 32A
ATS Mounting Bracket w Cord

Mounting Bracket with Cord Retention Tray
Free

  • 19″ rack mount kit for ATS
  • Cord retention tray for cabling management
  • Easy installation
Lockable IEC Outlets - InfraPower PDU

Lockable IEC Outlet

  • Lockable IEC outlet ATS models are available to secure plugs and prevent accidental disconnection
  • Support regular or switched IEC outlets
  • Compatible with our lockable IEC power cords for outlet locking features
  • Patented design for our ATS

Power Cords

Lockable Color Power Cords & Outlets - InfraPower PDU

Lockable IEC Colored Power cords

  • Patented design
  • Proprietary for InfraPower ATS & PDU
  • Applicable to standard IEC outlet in the market
  • VDE & ENEC approvals
  • Quality & cost effective
  • Easy to lock & secure
  • 6-colors : Black / Grey / Red / Blue / Orange / Green
  • C13-C14 (0.75mm²) : 0.5M / 1M / 2M
  • C19-C20 (1.5mm²) : 1M / 2M

Color UK Power Cord - InfraPower PDU

Colored UK Power Cord

  • Enhance cable management and visualize power sources
    Selection:
    Blue / Red
    UK – C13 (0.75 mm²): 3ft / 6ft